GVDA series single phase AC switching module
| This product is a multi-functional power module, which integrates thyristor power circuit, SCM-control phase-shift trigger circuit, signals detects and transfer circuit, voltage modulation circuit. It can realize the precise control of the voltage of the load. With built-in linear control circuit, it is highly precise and stabilized. Rated current: 50-500A, rated voltage: 220V, 380V, 440V, 50Hz or 60Hz. It is widely used in all kinds of induction and impedance loads, for instance: AC motor, transformer, temperature control, light change, AC voltage modulation. | Internal connection, classification and name

Main technical standards(GVDA-50;70;120;200;250;350;500)
| Function |
Thyristor AC single-phase voltage modulation |
| Input voltage |
220V+20% 380V+20% 440V+20% |
| Asymmetry degree of output positive and negative waves |
≤2% |
| Controlling voltage |
0-10VDC (input resistance 10KΩ) |
| Controlling current |
4-20mA (input resistance 330Ω) |
| Hand-control potentiometer resistance |
10KΩ |
| Colling method |
Wind-colling radiator |
| Ambient temperature |
-30oC~ +40oC |
| Storage temperature |
-25oC~ +55oC |
| Main circuit parameter |
| Parameter |
Unit |
Value |
| Load current |
Arms |
50 |
70 |
120 |
200 |
250 |
350 |
500 |
| TRIAC over voltage |
Vpk |
800-1200 |
| Frequency |
Hz |
50-60 |
| Off state voltage rising rate |
V/sec |
500 |
| On state voltage rising rate |
A/sec |
100 |
| Off state leakape current |
mArms |
≤8 |
≤10 |
≤10 |
≤10 |
≤15 |
≤20 |
≤20 |
| On state leakape current |
Vrms |
1.6 |
1.6 |
1.6 |
1.8 |
1.8 |
1.8 |
1.8 |
| Voltage drop insulating voltage |
Vrms |
≥2500 |
| Weight |
Kg |
0.425 |
2.2 | Exterior and installation dimensions
Connections of control lines(50-120A module) ■ 10V voltage control ■ 10K potentiometer control ■ 4-20mA control
| Remarks:the interfaces of 200A—500A modules:VCC(red)、CON1(blue)、Econ(orange)、CON(yellow)、4-20mA(green)GND(black)others are blank See the right map connections is the same as above. |

Dimensions

| |