Control Relays - GV series integration phase control moduleThe GV series voltage adjustable integrated solid state module is newly developed according to customers’ requests. It is characterized by input-output photoelectric isolation, integrated phase shift voltage adjustable circuit with main circuit, smart size, light weight, long service lifetime, big control power, stepless adjustment and high insulation voltage etc. It can control power of loads on output side automatically by changing the input voltage or by potentiometer manually. Meanwhile, due to its high input resistance and internal synchronization, through digital analogue converter, it can connect to computer, digital remote control, 0~5V or 4~20mA meters directly and make stepless adjustment for voltage, power of loads on output side conveniently. The TRIAC output are mainly applicable for resistive loads; The SCR output are mainly applicable for inductive loads. This product is widely used for lighting adjustment in illumination devices, temperature control in civil and industrial heating and soft start control etc
Features
- Standard structure and convenient mounting - Photoelectric isolation between input and output; the isolation voltage up to 2500V - Insulation voltage: 2500V - Adopting “vacuum + hydric protection” soldering SCR wafer technology for copper bottom plate - the anti-parallel SCR for those models with suffix “H”, good heat performance and long service lifetime - Input control voltage: DC5V - Control signal: automatic: 0~5Vdc or 4~20mA, manual: 10K potentiometer - Rated working voltage: 240V;440V - Max output current: 10~120A
Characteristic
| Dielectric strength (Input-Output) |
2500Vrms |
| Dielectric strength (Input-Output/Case) |
2500Vrms |
| Input control voltage |
5Vdc |
| Control signal(Automatism control )(Manual control) |
0~5Vdc OR 4~20mA 10K potentiometer |
| Operational voltage |
|
| Operational current (Max.) |
|
Ordering key
| G |
V |
80 |
24 |
D |
H |
| 1 |
2 |
3 |
4 |
5 |
6 | 1. Greegoo module 2. Single phase control 3. Operational current 4. Operational voltage 5. Control mode 6. Output device
Type selection
| Operational current (Max.) |
10,15,25,40,60,80,100,120A |
| Operational voltage |
24:240V 44:440V |
| Control mode |
automatism: 0~5Vdc 4~20mA manual: 10KΩ |
| Output device |
H: SCR Blank: Triac (For example: GV1524D) |
Model number
| Voltage |
Output Mode |
10A |
15A |
25A |
40A |
| 240Vac |
TRIAC |
GV1024D |
GV1524D |
GV2524D |
GV4024D |
| 440Vac |
GV1044D |
GV1544D |
GV2544D |
GV4044D |
| 280Vac |
SCR |
GV1028DH |
GV1528DH |
GV2528DH |
GV4028DH |
| 480Vac |
GV1048DH |
GV1548DH |
GV2548DH |
GV4048DH |
| Voltage |
Output Mode |
60A |
80A |
100A |
120A |
| 280Vac |
SCR |
GV6028DH |
GV8028DH |
GV10028DH |
GV12028DH |
| 480Vac |
GV6048DH |
GV8048DH |
GV10048DH |
GV12048DH |
Specifications
| Parameter-list ① Output device TRIAC |
| Parameter |
Units |
Specification Limits |
| Model No. GV |
|
10A |
15A |
25A |
40A |
| Input parameters |
| Control voltage |
Vdc |
5 |
5 |
5 |
5 |
| Signal voltage range |
Vdc |
0-5 |
0-5 |
0-5 |
0-5 |
| Input current (Max.) |
mAdc |
<20 |
<20 |
<20 |
<20 |
| Potentiometer |
KΩ |
10 |
10 |
10 |
10 |
| Output parameter (10-40A Triac) |
| Load current range |
Arms |
0.05-10 |
0.05-15 |
0.05-25 |
0.05-40 |
| Surge current 20mSec(Max.) |
Arms |
85 |
115 |
230 |
400 |
| Phase-shifting range |
0-175° |
| VDRM/VRRM(240V) |
V |
≥600 |
| VDRM/VRRM(440V) |
V |
≥1000 |
| Frequency domain |
Hz |
47 to 63 |
| Min. Off-state dv/dt |
V/μ sec |
100 |
| Max.Off-state leakage current |
mArms |
<5 |
| Thermal resistance (Rthjc) |
℃/W |
2.5 |
2.5 |
1.3 |
1.1 |
| Papameter-list ② H:Output device SCR |
| Parameter |
Units |
Specification Limits |
| Model No. GV |
|
10A |
25A |
40A |
60A |
| Output parameter (10-40A SCR) |
| Load current range |
Arms |
0.05-10 |
0.05-25 |
0.05-40 |
0.05-60 |
| Surge current 20mSec(Max.) |
Arms |
200 |
300 |
400 |
600 |
| Phase-shifting range |
0-175° |
| VDRM/VRRM(280V) |
V |
≥800 |
| VDRM/VRRM(480V) |
V |
≥1200 |
| Frequency domain |
Hz |
47 to 63 |
| Min. Off-state dv/dt |
V/μ sec |
500 |
| Max.Off-state leakage current |
mArms |
≤8 |
| Thermal resistance (Rthjc) |
℃/W |
2.5 |
2.5 |
1.3 |
0.65 |
| Parameter-list ③ H:Output device SCR |
| Parameter |
Units |
Specification Limits |
| Model No. GV |
|
80A |
100A |
120A |
| Input parameters |
| Load current range |
Arms |
0.05-80 |
0.05-100 |
0.05-120 |
| Surge current 20mSec(Max.) |
Arms |
1000 |
1200 |
1500 |
| Phase-shifting range |
0-175° |
| VDRM/VRRM(280V) |
V |
≥800 |
| VDRM/VRRM(480V) |
V |
≥1200 |
| Frequency domain |
Hz |
47 to 63 |
| Min. Off-state dv/dt |
V/μ sec |
1500 |
| Max.Off-state leakage current |
mArms |
≤10 |
| Thermal resistance (Rthjc) |
℃/W |
0.5 |
0.3 |
0.3 |
| General Specification ③ |
| Dielectric strength(Input/Output) |
Vrms |
2500 |
| Dielectric strength (Input-Output/Case) |
Vrms |
2500 |
| Ambient Operating Temperature Range |
|
–30 to +80 ℃ |
| Ambient Storage Temperature Range |
|
–30 to +80 ℃ |
| Weigh:(typical) |
|
144 g |
| Case Color |
|
Black |
| Mounting Dimensions |
|
L×W×H 58×44.5×24.5 mm |

Wiring diagram(Automatism control & Manual control)


Note:Heat sinking required | |