3 phase SSR (triac output 10A to 40A)
Print this pagePrint this page
Bookmark this pageBookmark this page
Tell a friendTell a friend
Live MessengerLive Messenger
Skype MeSkype Me
E-mail UsE-mail Us
Consulting Product InformationConsulting Product Information


3 phase SSR (triac output 10A to 40A)

GT 10 to 40 Amps AC SSR

The series GT three phase Solid State Relays is used three phase loads. Triac Output. The triac version of the zero switching relay is an inexpensive solution for resistive loads. The zero switching relay switches on when the AC sine voltage just crosses zero, and switches off when the current crosses zero.

- Three phase Solid State Relays
- Rated operational current 3x10, 3x15, 3x25 and 3x40 Amps.
- Rated operational voltage 440 V.
- Zero switching for resistive loads.
- Input Voltage Range 4 to 16 Vdc, 3 to 32 Vdc.
- 2500 Vrms Optical Isolation.(input/output)
- LED-indication for control input.

Ordering Key

GT_10_to_40_Ordering_Key

1. Greegoo brand;
2. Switch type:S - small size (1-5A), D - single phase, T - three phase;
3. Output method, blank - triac output, H - SCR output;
4. Rated working current (A);
5. Rated working voltage (V) (24:240V,44:440V,48:480V);
6. Control method Z - Zero, R -Random;
7. Control voltage D:3-8V, D1 -4-16VDC, D3 - 3-32VDC, A2 -90-250VAC.

Type Selection

- Mounting type T:AC Three phase Solid State Relay
- Operational current 10:3*10Amp, 15:3*15Amp, 25:3*25Amp, 40:3*40Amp
- Operational voltage 44:440VAC.
- Switched mode Z:Zero Voltage
- Input Control voltage

Selection guide

Voltage
Control
Rated operational current
voltage
10 Amp
15 Amp
25 Amp
40 Amp
440 VAC
4~16 Vdc
GT1044ZD1
GT1544ZD1
GT2544ZD1
GT4044ZD1
440 VAC
3~32 Vdc
GT1044ZD3
GT1544ZD3
GT2544ZD3
GT4044ZD3
440 VAC
4~16 Vdc
GT1044RD1
GT1544RD1
GT2544RD1
GT4044RD1
440 VAC
3~32 Vdc
GT1044RD3
GT1544RD3
GT2544RD3
GT4044RD3

Specifications

INPUT PARAMETER ① D1 D3
Control Voltage Range 4 to 16Vdc 3 to 32Vdc
Input Current (Max.) 26/86 mAdc @=5V/12V 25/28 mAdc @=5V/12V
Must Turn On Voltage 4Vdc 3Vdc
Must Turn Off Voltage 1Vdc 1Vdc
Reverse Voltage (Max.) 32Vdc 32Vdc
Display LED Yes Yes


OUTPUT PARAMETER ② Units Specification Limits
Model No. GTH 10A 15A 25A 40A
Load Current Range Arms 3X10 3X15 3X25 3X40
Surge Current, 20 mSec (Max.) Arms 85 115 230 400
Load Voltage Range Vrms 44 to 440
TRIAC Over voltage Vpk ≥1000
Frequency Range Hz 47 to 63
Min. Off-state dv/dt V/μsec 200
Off State Leakage Current (Max.) mArms ≤8
On-State Voltage Drop (Max.) Vrms 1.6
Thermal Resistance, (Rthjc) ℃/W 2.5 2.5 1.3 1.3
Turn On Time (Max.) “Z” Cycle 1/2
Turn On Time (Max.) “R” mSec 1
Turn Off Time (Max.) Cycle 1/2


GENERAL SPECIFICATIONS ③
Dielectric (Input/Output) Vrms 2500 2500 2500 2500
Dielectric (Input-Output/Base) Vrms 2500 2500 2500 2500
Capacitance(Max.) pf 10 10 10 10
Ambient Operating Temperature Range –30 to +80℃
Ambient Storage Temperature Range –30 to +80℃
Weight: ( max.) Aluminum Base plate 310g, Copper Base plate 430g.
Case Color: Black
Mounting Dimensions: LXWXH 105X74X32.5mm
Dimension