Solid state relays (400 to 550A)
Print this pagePrint this page
Bookmark this pageBookmark this page
Tell a friendTell a friend
Live MessengerLive Messenger
Skype MeSkype Me
E-mail UsE-mail Us
Consulting Product InformationConsulting Product Information

Solid state relays (400 to 550A)

GDH 400 to 550 Amps AC SSR

Series GDH are power line relays allowing 400 to 550 Amps. switching power,with Voltage ratings from 28
to480 Volts A.C.
Series GDH is Dual SCR Power Hybrid technology provides highly efficient thermal management for greatly
increased cyclic life.

·High power and high current.
·High performance/low cost circuit design.
·Logic compatible current regulated input.
·4000 Vrms optical isolation.
·Both “Zero Voltage” & phase controllable “Random Switching” versions.
·High voltage (1200 Vpk) versions for 480 Vrms service.
·LED-indication for control input.
·Control voltage range:4 to 16 Vdc,3 to 32 Vdc or 90 to 250Vac.
·Industy standard “SCR Modules” package.

Ordering Key

GT_10_to_40_Ordering_Key

1. Greegoo brand;
2. Switch type:S-small size (1-5A),D-single phase,T-three phase;
3. Output method,blank-triac output,H-SCR output;
4. Rated working current (A);
5. Rated working voltage (V) (24:240V,44:440V,48:480V);
6. Control method Z-Zero,R-Random;
7. Control voltage D:3-8V,D1-4-16VDC,D3-3-32VDC,A2-90-250VAC.

Type Selection

·Mounting type
·Rated operational current
·Rated operational Voltage
·Switched mode
·Input Control voltage
DH:AC Single phase,SCR Output.
400:400Amp,450:450Amp,500:500Amp,550:550Amp.
28:280VAC,48:480VAC.
Z:Zero Voltage,R:Random Switching.
D1:DC 4 to 16V,D3:DC 3 to 32V,A2:AC 90 to 250V.

Selection guide

Voltage Control voltage Rated operational current
400 Amp 450 Amp 500 Amp 550 Amp
280 VAC "Zero Voltage" 4to16 Vdc GDH40028ZD1 GDH45028ZD1 GDH50028ZD1 GDH55028ZD1
3to32 Vdc GDH40028ZD3 GDH45028ZD3 GDH50028ZD3 GDH55028ZD3
90to250Vac GDH40028ZA2 GDH45028ZA2 GDH50028ZA2 GDH55028ZA2
280 VAC "Random Switching" 4to16 Vdc GDH40028RD1 GDH45028RD1 GDH50028RD1 GDH55028RD1
3to32 Vdc GDH40028RD3 GDH45028RD3 GDH50028RD3 GDH55028RD3
90to250Vac GDH40028RA2 GDH45028RA2 GDH50028RA2 GDH55028RA2
480 VAC "Zero Voltage" 4to16 Vdc GDH40048ZD1 GDH45048ZD1 GDH50048ZD1 GDH55048ZD1
3to32 Vdc GDH40048ZD3 GDH45048ZD3 GDH50048ZD3 GDH55048ZD3
90to250Vac GDH40048ZA2 GDH45048ZA2 GDH50048ZA2 GDH55048ZA2
480 VAC "Random Switching" 4to16 Vdc GDH40048RD1 GDH45048RD1 GDH50048RD1 GDH55048RD1
3to32 Vdc GDH40048RD3 GDH45048RD3 GDH50048RD3 GDH55048RD3
90to250Vac GDH40048RA2 GDH45048RA2 GDH50048RA2 GDH55048RA2

Specifications

Input Parameter ① D3 A2
Control Voltage Range 3 to 32Vdc 90 to 250Vac
Input Current (Max.) 13/16 mAdc @=5V/24V 29 mAac @=220V
Must Turn On Voltage 3Vdc 90Vac
Must Turn Off Voltage 1 Vdc 10Vdc
Reverse Voltage (Max.) 32Vdc /
Display LED yes yes

Output Parameter ② Units Specification Limits
Model No. GDH 400A 450A 500A 550A
Load Current Range Arms 00.05 to 400 0.05 to 450 0.05 to 500 0.05 to 550
Surge Current,20 mSec (Max.) Arms 6000 6800 7200 8000
Load Voltage Range (280V) Vrms 24 to 280
SCR interdiction voltage (280V) Vpk ≥800
Load Voltage Range (480V) Vrms 44 to 480
SCR interdiction voltage (480V) Vpk ≥1200
Frequency Range Hz 47 to 63
Min. Off-state dv/dt V/μsec 500
Off State Leakage Current (Max.) mArms ≤10
On-State Voltage Drop (Max.) Vrms 1/2
Thermal Resistance,(Rthjc) ℃/w 0.12 0.12 0.1 0.1
Turn On Time (Max.) “Z” Cycle 1/2
Turn On Time (Max.) “R” mSec 1
Turn Off Time (Max.) Cycle 1/2
Turn Off Time (Max.) “A2” mSec 40

General Specifications
Dielectric (Input/Output) Vrms 2500 2500 2500 2500
Dielectric (Input-Output/Base) Vrms 2500 2500 2500 2500
Capacitance pf 10 10 10 10
Ambient Operating Temperature Range –30℃ to +80℃
Ambient Storage Temperature Range g –30℃ to +80℃
Weight:( typical) 2200g
Base plate:Copper,nickel-plated
Case Color:Black
Mounting Dimensions: LxWxH 126x63x66 mm

Dimension

GDH 400 to 550 Amps AC SSR